II 2G Ex ia IIC T6 Gb

Published: 08/05/2021

#CFAC#EPDS#Ex documentation#Ex personnel competency#ExAM#ExMediator#Explosion protection#non-electrical explosion protection#onlinEx

II 2G Ex ia IIC T6 Gb

"ia" way of Ex protection enables the installation to be installed as category 1 device - location of it might be Zone 0 / 20 - it may cover an electrical, but non.electrical installation as well (certainly of non.electrical device the marking shall be Ex h acc to iso 80079-37.

Here EPL says Gb, which means to be location of Zone 1/21.

So where to?

Right answer here you can connect ia circuits in a JB installed in Zone 1.

It is not a mistake, in case of an Ex inspection: pass.

Note: II 2G Ex ia IIC T6 Gb - above ground in possible gas hazardous environment Zone 1 as category 2 device, standardized solution, protection method ia, gas hazardous environment: hydrogen - acetylen as representative gases, maximum surface temperature: 85 (80) C, EPL defined as per Gb.

Keep up good work!

Arpad

veress@exprofessional.com

exprofessional.com